Subject: From: Date: | RE: [ECS] "Missed" DIGITAL-INPUT-K changes ? Doug Storey Sun, 14 Jan 2001 22:28:44 -0600 |
Warren;
Supervised digital input IS jumper on pins 2 and 3. If you use a Multi-meter
you can see that with the jumper on 2 and 3 there is an output voltage. If
the Jumper is on 1 and 2 there is none. Don't mean to be insulting but do
you have the 1K resistor in place?
When you place a meter on the PIR does the meter go to 0 when detecting
motion?
Is this a Normally Closed circuit ? ( A potential customer is reporting such
a problem with a PIR that opens the contact "briefly". )
-----Original Message-----
From: Warren.Hughes@newzealand.sun.com
[mailto:Warren.Hughes@newzealand.sun.com]
Sent: Sunday, January 14, 2001 2:15 PM
To: ecs-list@netbloc.com
Subject: Re: [ECS] "Missed" DIGITAL-INPUT-K changes ?
Hi Chaps, guess what, I emailed Applied Digital and this is the result:
----
Place the pins on 2 and 3. I'm still working on it.
Kevin Barrett
Have a great day
----
The above doesnt work at all; I am sure its meant to be 1+2.
I wonder if my SECU-16 to Ocelot to PC communication is just not fast
enough, has anyone had lag problems like this?
Cheers, Warren
Doug Storey wrote:
>
> No, It is a jumper. The SECU-16 Manual has conflicting data on how to set
> the jumper in section 3.1. I think Warren Hughes was going to contact
> Applied Digital
>
> -----Original Message-----
> From: Mark Gilmore [mailto:omnip@usit.net]
> Sent: Friday, January 12, 2001 8:06 AM
> To: ecs-list@netbloc.com
> Subject: Re: [ECS] "Missed" DIGITAL-INPUT-K changes ?
>
> Hi Doug,
> Was this a change you had to make from a CMAX setup default ?
> Is this something I need to doc in ECS.HTM ?
> Thanks,
> --
> Mark Gilmore
> Omnipotence (ECS home automation software)
> http://omnipotencesoftware.com
> 423-745-0026
> Hours: Mon-Sat, 9AM-8PM/EST
>
> Doug Storey wrote:
> >
> > Yes but the problem was that I was using the 4-20ma input setting rather
> > than supervised.
> >
> > -----Original Message-----
> > From: Mark Gilmore [mailto:omnip@usit.net]
> > Sent: Sunday, January 07, 2001 3:34 PM
> > To: ecs-list@netbloc.com
> > Subject: [ECS] "Missed" DIGITAL-INPUT-K changes ?
> >
> > Hi all,
> > Has anyone ever seen ECS "miss" a change on
> > a DIGITAL-INPUT-K Item (OCELOT/SECU-16) ?
> > A potential customer is reporting such a problem
> > with a PIR that opens the contact "briefly".
> > Thanks,
> > --
> > Mark Gilmore
> > Omnipotence (ECS home automation software)
> > http://omnipotencesoftware.com
> > 423-745-0026
> > Hours: Mon-Sat, 9AM-8PM/EST
subject (prev) or (next) |