RE: [ECS] hv dimming
Ingo Dean (At Home)
Sun, 4 Oct 1998 18:13:32 -0400

I don't use any wall switches, I only use the regular X-10 Lamp Modules (and
some Radio Shack Plug&Power Lamp Modules).  And the lights do dim to 0%
properly when using Homevision's commands only, or using an X-10 controller.

Before ECS, Homevision never had this problem.  I've been dimming my lights
to 0% for years.

> -----Original Message-----
> From: Dan Carrington [mailto:dc_grafx@microworks.net]
> Sent: Sunday, October 04, 1998 5:09 PM
> To: ecs-list@vancouver.ml.org
> Subject: Re: [ECS] hv dimming
>
>
> Something to consider.  It could be the X10 dimming units themselves.  I
> have some Newtone decora wall switches that are standard X10 dimming.
> If I send an on command from a remote and then hold down the dim button
> on the remote, the light will come on then dim down to off.  If I
> actually look closely at the lightbulb filliment and listen carefully, I
> can see the filliment glow slightly and hum at 60hz.  The actual x10
> dimmer unit will not go fully off.  I can hold down the dim button till
> the cows come home and it will not go off further.  ECS will show that
> light at 0% as it should.  If I then hit the off button for that light,
> the light goes fully out and the humming stops.  This problem, mine at
> least, has nothing to do with ECS, just the way my wall switch works.
> Try that yourself and see what is the problem.
>
> Dan Carrington
>
>
>
>
> Ingo Dean (At Home) wrote:
> >
> > Mark,
> >
> > > From: Mark Gilmore [mailto:markgilmore@cococo.net]
> > > Sent: Tuesday, September 29, 1998 10:33 PM
> > ...
> > > Ingo, If you have used "SET ECS_PLC_IFC_2J_DIM=2", the fast
> > > HV/dimming should work (with 4 extra dims for 0%).
> > > If not, try the new one. If still not, is it dimming FAST ?
> >
> > I just downloaded and installed the "10/03/98 03:58PM 1,281,274 ECS.ZIP"
> > beta version.
> >
> > I again "SET ECS_PLC_IFC_2J_DIM=2" to have ECS use smooth Homevision
> > dimming.
> >
> > It does do fast dimming, but setting my lights to 0% still leaves them
> > glowing, just like before.
> >
> > Using Homevision's built-in TV screens, I verified that it (HV) also
> > believes the (still glowing) light to be at 0%, just like ECS.
> >
> > If you are sending the four extra DIMs, perhaps Homevision is
> ignoring them:
> > the regular "Dim ## Times" command (P{uc}07{fnc}) would be ignored by
> > Homevision once it "believes" the light is fully dimmed.  You should be
> > using the "Force Dim ## Times" command (P{uc}09{fnc}) so that
> HV's internal
> > view doesn't override your commands.  (Actually, you should be using the
> > Force versions wherever they exist to make sure Homevision never ignores
> > you.)
> >
> > Note also that I have this problem even without using the new fast-dim
> > option (to a lesser extent, though).  Many times, I have to "reset" my
> > lights because when I set them to 0% at night, they continue to
> glow.  But I
> > believe this to be a seperate issue:
> >
> > For more data, I had ECS dim a light and brighten it back one step at a
> > time, comparing the ECS and HV (screen) values after each step.
>  You can see
> > ECS and HV go out of sync both when dimming (at 6%) and brightening (at
> > 96%):
> >
> > Dimming                                 Brightening
> > ECS     HV                              ECS     HV
> > =========                       ===========
> > ON      100                             0       0
> > 96      93                              6       6
> > 90      87                              12      12
> > 84      81                              18      18
> > 78      75                              24      25
> > 72      68                              30      31
> > 66      62                              36      37
> > 60      56                              42      43
> > 54      50                              48      50
> > 48      43                              54      56
> > 42      37                              60      62
> > 36      31                              66      68
> > 30      25                              72      75
> > 24      18                              78      81
> > 18      12                              78      81
> > 12      6                               84      87
> > 6       0<-LIGHT WENT OFF               90      93
> > 0       0                               96      100
> >                                         ON      100
>