Re: [ECS] micro-redac and relays
don.NoSpam.sb.net
Thr, 24 Dec 1998 12:51:44 +700

On 1998-12-24 ecs-list@netbloc.com said:
   >The first thing to be sure of is what the relay on the back of your
   >receiver really is.

Good point. If it IS a dry contact, ie if it makes and breaks a circuit
then you need to define a digital input in ECS and have it look at the
digital input of the MicroRedac. Once this is done install a 5vt source
and run one lead to the numbered connector of the Micro Redac, and the
other to one side of the dry contact on the receiver. Run another wire
from the other side of the dry contact to the common digital contact on the
Micro Redac. I'm not sure if polarity is an issue, but someone else will
probably correct me if it is a problem.