ECS-L Home Automation and Security Archives
  learn more | view messages for this month | NetBloc® | terms of use | search

Google
 


  subject (prev) or (next) | time (prev) or (next) | author (prev) or (next) | view more subjects

Subject:
From:
Date:
Re: [ECS] LM14A problems fixed?
Mark Gilmore
Wed, 30 Dec 1998 08:46:40 -0800

What happens if you use ECS to send a unit-selection
command followed by 1 dim command (via a PLC-Command Item) ?
I assume you are using a LIGHT Item, rather than LIGHT/A.

Timothy G. Mulle' wrote:
> 
> Mark:
> 
> Nope.. I use the ActiveHome software that came with the CM11A and it all
> works fine. I can dim the LM14A's and operate any 2-way device without
> lockup.
> 
> -----Original Message-----
> From: Mark Gilmore [mailto:omnip@usit.net]
> Sent: Tuesday, December 29, 1998 3:46 PM
> To: ecs-list@netbloc.com
> Subject: Re: [ECS] LM14A problems fixed?
> 
> Tim, I remember - I wanted to know if sending the same
> commands with the CM11A software would also cause
> the CM11A to lockup.
> --
> Mark Gilmore
> Omnipotence (Home Automation Software)
> omnip@usit.net
> http://www.usit.com/omnip

-- 
Mark Gilmore
Omnipotence (Home Automation Software)
omnip@usit.net
http://www.usit.com/omnip