Subject: From: Date: | Re: [ECS] ADPCM and CID question Greg Johnson Tue, 19 Jan 1999 20:28:04 -0800 (PST) |
The error ADPCM error message comes right when I start up ECS. It
Initializes and then starts the TTS engines. I"m using the SDK engines. I
did have:
Speech Engine: Microsoft Speech Synthesis Engine: Mary in Hall
Phone Engine: Microsoft Speech Synthesis Engine: Mary (for Telephone)
Right after the speech engines initialized it said:
Creating TTS file...
Then it would come back with the error:
PM:Unsupported rate for ADPCM compression (8000HZ) (Item "Catbox Msg")
I changed the Phone speech engine to just: Mary (without "for telephone")
and it didn't give the same error. It did however say something else.
PM: Open error on "c:TTS.RPC" (Item "Catbox Msg")
It looks like it is trying to write a file to the c: drive?
ECS is installed: d:\ecsfull
Greg
> Greg, I need to know that you are doing to trigger
> this error.
>
> Greg Johnson wrote:
> >
> > Hi,
> >
> > I'm getting the following errors:
> > "PM:Unsupported rate for ADPCM compression (8000HZ)"
> > I checked the ADPCM settings in the control panel and they are set to "all
> > rates". I'm using a Ensoniq sound card which hasn't had any troubles in
> > the past. Is this a win98 or ECS setting?
> >
> > I also have a cheap BTC 56IP modem which i was using for caller id in the
> > past. It has the Rockwell chipset and does respond ok to the "AT#CID=1"
> > command. When I get a new call it detects the number of rings fine, but
> > the caller id info never seems to make it. The modem will call out and
> > record so it seems like it is recognized by the system ok. Any ideas?
> >
> > Phn_c.set file:
> > |ATZ // reset
> > ?|AT$$H8&W // disable HOT-SCAN feature
> > |ATX4 // send ALL responses
> > |AT#CID=1 // enable caller-id
> > |AT#CLS=8 // enter voice mode (for DTMFs, etc)
> > |AT#VTD=FF,FF,FF // ena ALL DTMFs, ALL modes
> > |AT#VRA=60 // remote phone "answered" if no ring after 6 secs
> > |AT#VRN=60 // remote phone "answered" if no ring after 6 secs
> > |AT#VBT=1 // .1 sec beeps
> > ?ATS30=60 // assure recovery if DTE dies (???)
> > |AT#VSP=50 // silence tmo = 5 secs ???
> > |AT#VLS=4 // line-input, spkr & line/handset ena
> >
> > Thanks,
> > Gregory Johnson
> > diggins@teleport.com
>
> --
> Mark Gilmore
> Omnipotence (ECS Home Automation Software)
> Voice:423-745-0026
> FAX :423-745-1714
> omnip@usit.net
> http://www.usit.com/omnip
>
Gregory Johnson
diggins@teleport.com