Subject: From: Date: | Re: [ECS] Problem with Backup States Ingo Dean Sun, 21 Feb 1999 12:46:26 -0500 |
Thanks, Mark, you led me in the right direction.
Here's what happened:
My "Daytime" True/False item was not set to backup, but had a Initial state of
"True".
My "Day/Night" event used an "If Daytime Is Now False" conditional to set my
MBR Light to 42% at dusk.
So the first event pass after an ECS restart would always set my Daytime
variable from True to False, which allowed my Day/Night event to start dimming
the light.
Unfortunately, that doesn't explain why ECS didn't turn the light off and on
to set it to a known state first like it does for everything else. Probably
has something to do with either the event order or the fact that it was in the
first event pass? You might want to check into this, still.
Anyway, now that I set Backup: True on my Daytime item, the light behaves
properly on ECS startup at night - it turns off, then on, then dims to 42%,
the Backup state of that item.
Mark Gilmore wrote:
> Ingo,
> ECS.BK stores backup states, as it would not be
> practical to update ECS.CFG every state change.
> I just tested backup on a lamp: Set it to ON,
> exited, re-started - worked OK. Then repeated
> with a settng of 48% - still worked fine.
> So it looks like an Event is resetting your
> light at startup, OR perhaps a PLC-COMMAND
> or PLC-BUTTON Item is set for backup (which would
> not make sense, but could cause such a problem).
>
> Ingo Dean wrote:
> >
> > Mark,
> >
> > I thought that when I set the "Backup" to Yes on an Item, that ECS
> > actually writes a new copy of ECS.cfg every time that the state changes
> > to update that value. I have several Light items that I has set to
> > Backup:Yes, but ECS.cfg never gets updated.
> >
> > Or does it work differently? (ECS.bk seems to get updated every time, do
> > you use that instead of the Initial State field in ECS.cfg?).
> >
> > Seperately, my "MBR Light" never comes on correctly after an ECS
> > restart. Even though the item is set to Backup:Yes and ECS does show it
> > to be at 42%, the lamp is always off after a restart. This happened
> > even in version 3.4
> >
> > Oh, even though I'm running version 4.0.018, the first line of my
> > ECS.cfg states 3.4.026
> >
> > ----
> > Work: mailto:Ingo_Dean@MentorG.com Personal: mailto:idean@iname.com
> > http://www.geocities.com/Hollywood/Hills/2948/
>
> --
> Mark Gilmore
> Omnipotence (ECS Home Automation Software)
> omnip@usit.net
> http://www.usit.com/omnip
--
----
Work: mailto:Ingo_Dean@MentorG.com Personal: mailto:idean@iname.com
http://www.geocities.com/Hollywood/Hills/2948/