ECS-L Home Automation and Security Archives
  learn more | view messages for this month | NetBloc® | terms of use | search

Google
 


  subject (prev) or (next) | time (prev) or (next) | author (prev) or (next) | view more subjects

Subject:
From:
Date:
Re: [ECS] Phone C Recordings
Carl Keyes
Tue, 16 Mar 1999 07:44:04 +0000
Tue, 16 Mar 1999 07:44:04 +0000
Mark,

The modem is a:
Supra 56i Voice V.90  Hardware ver. 1.0.00

What I'm trying is setting the state of the Phone-Interface-C
item to  "Record Local Message" in the Group screen.
Then I get the error message:
"Modem not responding to "AT#VLS=1"

Attached is the ELG.tmp while attempting the above.
 

The other modem related problem I have is getting
the phone-c item reset after a WPDL download.

The error message reads :
Open error on Com5 (W95#5:Access is denied)
when I attempt a "Reset".

I have the modem set up on Com5.

Thanks,

Carl

Mark Gilmore wrote:

> Carl,
> What is the full make/model# of this modem ?
> It is VERY IMPORTANT that you give me a step-by-step
> description of what you are doing. For example,
> I don't know what you did to try to record "thru
> the phone").
>
> Please:
> 1) Delete ELG.TMP.
> 2) Press ctrl-x
> 3) Set a PHONE-RECORDING-C Item to RECORD
> 4) Wait a few secs
> 5) Kill STOP (if visible).
> 6) Press alt-x
> 7) Email me ELG.TMP.
> Please send this and other email related to
> specific testing to me directly.
> Thanks.
>
> Carl Keyes wrote:
> >
> > Mark,
> >
> > I tried to make a Phone-C rec. (thru the phone)
> > and got the error message:
> >
> > Modem not responding to: "AT#VSL=1"
> >
> > When I set the item to record I did get the start-stop menu.
> > When I finished the recording I pressed stop and
> > the message field read "Coverting to Wav" or something
> > to that effect. Then the "modem not responding" message
> > followed and no sound was played.
> >
> > Later,
> >
> > Carl
>
> --
> Mark Gilmore
> Omnipotence (ECS Home Automation Software)
> omnip@usit.net
> http://www.usit.com/omnip

  


 7:24:21: MODEM-TX (07:24:21):
<CR><CR><CR><CR>
 7:24:21: MODEM-RX (07:24:21):
<CR><CR><CR><CR>
 7:24:21: MODEM-TX (07:24:21):
AT#VLS=1<CR>
 7:24:21: MODEM-RX (07:24:21):
AT#VLS=1<CR><CR><LF>
ERROR<CR><LF>
 (IGNORED)
 7:24:23: CMD_MDM:ERR=Modem not responding to "AT#VLS=1"
 7:24:23: CMD_MDM:RETRY
 7:24:23: MODEM-TX (07:24:23):
AT#VLS=1<CR>
 7:24:23: MODEM-RX (07:24:23):
AT#VLS=1<CR><CR><LF>
ERROR<CR><LF>
 (IGNORED)
 7:24:25: ERROR:Modem not responding to "AT#VLS=1"
 7:24:25: ANA_INP_G_RD:reading AI Temp Outside
 7:24:26: PLC2G-TX (07:24:26):
##%3380050000<CR><CR> RX:###%3300<CR><LF>

 7:24:26: ITM_STT_DBG:28:AI Temp Outside=0
 7:24:26: ANA_INP_G_RD:reading AI Temp Inside
 7:24:26: PLC2G-TX (07:24:26):
##%3380040000<CR><CR> RX:###%3321<CR><LF>

 7:24:27: ITM_STT_DBG:28:AI Temp Inside=33
 7:24:27: ANA_INP_G_RD:reading AI Light Sensor
 7:24:27: PLC2G-TX (07:24:27):
##%3380030000<CR><CR> RX:###%339a<CR><LF>

 7:24:27: ITM_STT_DBG:28:AI Light Sensor=154


  subject (prev) or (next) | time (prev) or (next) | author (prev) or (next) | view more subjects




Services provided by [NetBloc]®! NetBloc Solutions Inc.
Terms of use. Indexing software (c) 1999 Lin-De, Inc
.