| ECS-L Home Automation and Security Archives |
| Subject: From: Date: | RE: [ECS] Beta upload Timothy Mulle' Thu, 18 Mar 1999 16:56:07 -0500 |
When I try to run the latest beta I get: 4:52:30: ERROR:Invalid Relational-Operator "Set" (line 503) I am running the lite.cfg file and I assume it is looking in the lite.cfg file when this error happens. This is what is at the line 503: This config file worked fine in the last beta before this one. |Event: Startup Called ?:No | Performs the following on the 1st pass: | | 1) The 2001 theme is played. | 2) A startup message is displayed | 3) Sets "D.S.T. IN EFFECT" TRUE if daylight-savings is | definitely in effect. | ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ | If Start/Stop-Status Is Not Starting | Then Event-Exit Set True | | Do 2001 Theme Set Play | Do Startup Message Set Display | | If Month Is April | And Date Is GT 7 | Or Month Is GT April | And Month Is LT October | Or Month Is October | And Date Is LT 25 | Then D.S.T. In Effect Set True Line 503+> | Else D.S.T. In Effect Set False | End Any ideas? - Tim > -----Original Message----- > From: Mark Gilmore [mailto:omnip@usit.net] > Sent: Thursday, March 18, 1999 3:56 PM > To: ecs-list@netbloc.com > Subject: [ECS] Beta upload > > > ECSB.ZIP (ECS.EXE only) has been uploaded, and > incorporates the following changes (download by clicking > "BETA SOFTWARE" at the bottom of http://www.usit.com/omnip). > Note: I also improved the logic which tracks the States > of LIGHT/B Items when ECS monitors commands sent to the > corresponding modules. > > 4.0.024 (03/??/98) > > 75) Corrected a problem with the TimeCommander > (PLC-INTERFACE-2G), > which could prevent ECS from properly tracking the States of > Light/Appliance Items. > > 76) ECS/WIN: Fixed a bug which prevented ECS from setting up > serial-ports for 7-bit word-lengths. I think any effects > were limited to PAGING and I/O via SERIAL-BYTE Items > (IF word-length was 7). > > 77) A new Type (LIGHT/B) has been added for use with the X-10 > LM14A & Leviton 6381 lamp modules (both of which support > "direct-level" dimming). > > 78) ECS/WIN: Improved Event Editor parser such that it properly > "expands" partially-entered operators (e.g. "D X M X" would > expand to "Do X Multiply X"). Also, if a partial Item-name > is entered , it now expands to the first matching Item-name > in the choice-list (alphabetical) rather than the first in > ECS.CFG. > -- > Mark Gilmore > Omnipotence (ECS Home Automation Software) > omnip@usit.net > http://www.usit.com/omnip >