ECS-L Home Automation and Security Archives
  learn more | view messages for this month | NetBloc® | terms of use | search

Google
 


  subject (prev) or (next) | time (prev) or (next) | author (prev) or (next) | view more subjects

Subject:
From:
Date:
Re: [ECS] IR Master Model 100S
Mark Gilmore
Thu, 24 Jun 1999 05:55:20 -0700

Steve,
In ECS.DT, you will find these lines:
	IR2B-2 TX Hdr (3-4)   :21 87
	IR2B-2 RX Hdr (2-6)   :2a 96 79 21 0f 
	IR2B-3 TX Hdr (3-4)   :87 04
	IR2B-3 RX Hdr (2-14)  :2a 78 3c 0e 0f 03 06 e1 38 0c 2d 01 00 

IF yours differ from these, find a procedure which
will dependably replicate the problem (for testing).
Then change your ECS.DT lines to match the above
and re-test.

> Steven M. Eaton wrote:
> 
> I have a Dancraft IR Master Model 100S. I purchased this back in
> Feb./Mar. time frame. I have it working but have been experiencing
> where the unit will lockup at times when ir commands are sent. Then
> you have to power the unit off and back on before it will start
> working again with ECS. I have relearned the ir commands that I have
> defined several times, tried changing the signal delay, and changing
> the buffer size as well even though I am sending only one command when
> it locks up. It t does this on various commands, and not just one. I
> was wondering if any of you that are using the Model 100S are
> experiencing any problems like this and if not, what do you have as
> the model under ECS? Are there any other suggestions that I could try
> to correct this problem? I have tried the model 100 and the 100X, but
> experience the lockups. Any help would be greatly appreciated.
> 
> 
> 
> 

-- 
Mark Gilmore
Omnipotence (ECS Home Automation Software)
omnip@usit.net
http://www.usit.com/omnip

  subject (prev) or (next) | time (prev) or (next) | author (prev) or (next) | view more subjects




Services provided by [NetBloc]®! NetBloc Solutions Inc.
Terms of use. Indexing software (c) 1999 Lin-De, Inc
.