4.1.006 BETA (8/24/99 2:30PM)
Mark Gilmore
Tue, 24 Aug 1999 11:27:42 -0700

http://www.usit.com/omnip/ecsl.zip has been uploaded.
Once again, I think the TX15B stuff will work :-).

	4.1.006 (08/24/99)

    71)	The TX15 and TX15-B X-10 thermostats are now directly supported
	via new Types HVAC-INTERFACE-C and HVAC-INTERFACE-D.

*   72)	The numeric PHONE-INTERFACE-D States have been replaced by names
	(the "PHONE-INTERFACE-DX" custom Type is no longer required).

    73)	Per #38 above, a problem has been corrected which prevented the
	CID info from being written to LMCID.TXT when PHONE-INTERFACE-D
	was used.

    74)	So as to free-up the CPU for other programs, ECS now "sleeps"
	when no activity is pending and it has not fallen behind by
	more than 1 second. A timer is used to assure that Events
	are executed at least 4 times/second.

    75)	Added new Item Type (ACTIVE-GROUP) to allow Events to display
	different Groups in the Group Screen.

    76)	In order to GREATLY increase the speed of cfg saves (as well as
	simplify the logic which does so), ECS now writes an entire new
	ECS.CFG on each save (rather than "surgically" searching/parsing
	the existing file). The only downside to this approach is that
	comments OUTSIDE of Events and any custom indentation you use
	within Events are no longer preserved.

    77)	A bug has been corrected which triggered an error msg if one
	attempted to edit an IR-SIGNAL-K Item whose Signal# was > 128.

    78)	Corrected problem with learning IR-SIGNAL-K Items whose Signal#s
	were > 80 (signal #'s >80 are NOT monitored by the CPU-XA).
	The signals WERE learned when received by the CPU-XA, but ECS
	did not notify the user.

*   79)	The Event "engine" logic has been overhauled:

	BEGINIF and WHILE statements may now be followed by additional
	AND/OR conditional statements.

	There is also a suttle difference in the way that the "IS NOW"
	operator works: Previously, ECS would detect the transition to
	the desired State if it had occured "since THIS Event was last
	executed". Now, it will be detected if it has occurred since ALL
	Events were last executed. Specifically, ECS saves the old States
	of all Items, reads the current States, and executes all Events.
	These old States are used in evaluating "IS NOW" conditions.
	I doubt that this change will effect the execution of anyone's
	Events, but I wanted you to know (just in case).

    80)	Fixed bug which could cause PHONE-RECORDING-C/VOICE-RECORDING-C
	files to be overwritten if entered manually in the Item Editor.

*   81)	BELL.WAV has been renamed to CLICK.WAV, and ERRBELL.WAV has
	been renamed to BELL.WAV.
	If you have upgraded via ECSL.ZIP, you should rename these
	files accordingly, as SETUP will not overwrite them.

    82)	Inovonics product descriptions/pricing are now included in
ECS.HTM.
-- 
Mark Gilmore