| ECS-L Home Automation and Security Archives |
| Subject: From: Date: | Re: [ECS] ECS 4.2.009 & Serial-Byte Bill Walters Sun, 16 Jan 2000 16:14:02 -0600 |
Mark, Lastly, entire event posted in the ECS archives as BWweeder.txt Bill ----- Original Message ----- From: Bill Walters <wtwalters@home.com> To: <ecs-list@netbloc.com> Sent: Sunday, January 16, 2000 4:11 PM Subject: Re: [ECS] ECS 4.2.009 & Serial-Byte > Mark, > > Oops........ Weeder T/C I is type "Telephone Interface", while Weeder > Telephone IX is type Serial-Byte. > > Sorry. > > Bill > > ----- Original Message ----- > From: Bill Walters <wtwalters@home.com> > To: <ecs-list@netbloc.com> > Sent: Sunday, January 16, 2000 4:09 PM > Subject: Re: [ECS] ECS 4.2.009 & Serial-Byte > > > > Mark, > > > > I don't understand how this change could cause a problem... If the value > is > > 'correct' at the start of each event pass, why would it not be 'correct' > > when referenced (if not at the start of the event-pass)... Anyway, here's > > the event in question (only down thru the offending line) > > > > > > |Event: Log Call Called ?:No > > | > > | ; Edited 8/18/99 > > | ; ECS DOS "Local-Phone-Button" references deleted > > | ; and changes made to reflect addition of Weeder telephone interface > > | ; which intercepts touchtones and after 5 seconds of silence, sends > > | ; them out in a string prefaced with "O" (Letter Oh, not zero), and > > | ; terminated with C/R > > | > > | If Weeder Telephone IX Is Disconnected > > | Then Event-Exit Set True > > | > > | If Weeder Telephone IX Is Not None > > | Then Weeder T/C I Set Weeder Telephone IX > > ..............rest of code ommitted.......... > > > > The last line shown is the line the code "chokes" on... BTW, Weeder > > Telephone IX is defined as type "Telephone-Interface", which is a custom > > type. There each of the ASCII values for 0...9,#,*, CR, are defined. > > Item Weeder T/C I is type State-Holder. > > > > There has not been a problem with this code since I put it into place. > > > > Bill > > > > > > > > > > > > > > > > ----- Original Message ----- > > From: Mark Gilmore <omnip@usit.net> > > To: <ecs-list@netbloc.com> > > Sent: Sunday, January 16, 2000 3:23 PM > > Subject: Re: [ECS] ECS 4.2.009 & Serial-Byte > > > > > > > Hi Bill, > > > Did you note this ? > > > * 197) SERIAL-BYTE and I/O-PORT-BYTE Items are now read when referenced > > > (instead of at the start of each Event-Pass). > > > > > > This may require an Event logic change. > > > I did not personally test it, but it apparently works > > > (for at least ONE customer :-)). Let me know if not. > > > -- > > > Mark Gilmore > > > Omnipotence (ECS home automation software) > > > http://www.usit.com/omnip > > > 423-745-0026 > > > > > > >