Re: [ECS] why won't my lights go off?
Mark Gilmore
Sat, 22 Jan 2000 18:16:37 -0500

AJ,
Your 1st BEGINIF will only occur when
DAYTIME is FALSE
AND FPM Is Now ON
-- 
Mark Gilmore
Omnipotence (ECS home automation software)
http://www.usit.com/omnip
423-745-0026


A.J. Griglak wrote:
> 
> They come on OK, the stereo turns off OK during the day, the timer is
> working right, yet when it gets to 0, the lights stay on...  anyone?
> 
> -=A.J.
> 
> BEGINIF    Daytime              Is         False
> And        front porch motion   Is Now     On
> Then       Front Porch Lights   Set        On
> Then       Front Porch timer    Set        10
> 
> IF         Front Porch timer    Is Now     0
> Then       Front Porch Lights   Set        Off
> 
> If         Front Porch timer    Is         0
> Then       Event-Exit           Set        True
> ENDIF
> 
> BEGINIF    Daytime              Is         True
> If         front porch motion   Is Now     On
> Then       A/V - Stereo         Set        Off
> ENDIF