Subject: From: Date: | Re: [ECS] Arguments Etc. Carl Keyes Thu, 20 Aug 1998 21:33:05 +0000 |
Mark Gilmore wrote:
>
> Carl, use HELP in TTS !
>
> Regarding the TC:
> Sounds like a serial-related problem.
> ECS assumes 2400 baud.
> If your model operates at a diff baud,
> override via "SET ECS_PLC_IFC_2G_BAUD={baud}".
> OTHERWISE, select the TC Item in the Item Editor,
> press <ctrl-x> and <alt-c> and <F5>.
> Then email me CPT.TMP.
>
Mark,
Bingo on the Baud change to 9600 for the TC+. But it's always something.
I just realized the Infrared expander I got with it plugs directly into
the TC+.
I'm assuming they cannot share, in this case, com2. I know the IR-XP can
be used
directly from a serial port but I'm fresh out. One other kind of major
thing is
my new X-10 PLM21 modules and Leviton 6381 wall swithches aren't
responding to on ,off or dim commands. I made the assumtion that the
Light/A
type supported pre-set dimming,(direct to a dim level without
stepping)but they
don't respond at all. I tried the WinEV software and they worked
perfectly.
Direct dimming is the only way to go. Will pre-set dimming be supported
any time soon?
Thanks,
Carl