| ECS-L Home Automation and Security Archives |
| Subject: From: Date: | Re: [ECS] NAPCO Support Mark Gilmore Sun, 06 Feb 2000 19:39:21 -0500 |
Hi Bill, Please accepy MY apologies, as I obviously misinterpreted your statement :-). The "GEMINI Home Automation Development Spec" is the only documentation I have on the Napco, and it provides VERY few details as to what is what. And having never even seen the unit, I know very little of it myself. I just focused on providing ALL the control and status monitoring that the protocol supported (with little regard paid the the particular meaning of each status message). SOME confusion regarding the RTS states is probably due my need to be "creative" with some abbreviations (given the 19-char limit). Let's see the following is any help. NOTE: I will merge this info in the next upload of ECS.HTM. ECS name Napco name ------------------------ ------------------------ About-To-Set-Clock About to set clock Ac-Fail AC Fail Ac-Rst AC RST Alarm Alarm Alarm-Super Alarm Supervisory Alarm-Super-Restore Alarm Supervisory Restore Auto-Arm-Dly-1-Hour Auto-arm delayed 1 hour Auto-Arm-Dly-2-Hour Auto-arm delayed 2 hours Auto-Arm-Dly-3-Hour Auto-arm delayed 3 hours Auto-Arm-Dly-4-Hour Auto-arm delayed 4 hours Auto-Arm-Disabled Auto-arm disabled Auto-BP-Zone-Re-Ent Auto-Bypass zone re-entry Burg-Bell-Silen Burg Bell silence Burg-Bell-Time-Out Burg bell time-out Bus-2-Fail Bus 2 Fail Bus-2-Restore Bus 2 Restore Bypass Bypass Close CLOSE Comm-Restored Comm Restored Date Date Day-Zone-Alarm Day zone Alarm Day-Zone-Rst Day zone RST Day-Zone-Tbl Day zone TBL Day-Zone-Tbl-Rst Day zone TBL RST Dealer-Mem-Fail Dealer mem fail Dealer-Pgm-Mode-Act Dealer pgm mode activity Digital-Dialer-Test Digital Dialer test Door-Access Door Access Ezm-Fail EZM Fail Ezm-Restore EZM Restore Ezm-Tamper EZM Tamper Ezm-Tamper-Rst EZM Tamper RST Fail-To-Close Fail to Close Fail-Cls-Dly-1-Hour Fail to close delayed 1 hour Fail-Cls-Dly-2-Hour Fail to close delayed 2 hours Fail-Cls-Dly-3-Hour Fail to close delayed 3 hours Fail-Cls-Dly-4-Hour Fail to close delayed 4 hours Fail-Close-Disabled Fail to close disabled Fail-To-Open Fail to Open Failure-To-Comm Failure to communicate FEZM-Tamper FEZM Tamper FEZM-Tamper-Rst FEZM Tamper RST Fire Fire Fire-Bell-Silence Fire Bell Silence Fire-Bell-Time-Out Fire bell time-out Fire-Bypass Fire bypass Fire-Drill Fire Drill Fire-Rst Fire RST Fire-Sup Fire Supv Fire-Sup-Rst Fire Supv RST Fire-Sup-Tbl Fire Supv TBL Fire-Sup-Tbl-Rst Fire Supv TBL RST Fire-Tbl Fire TBL Fire-Tbl-Rst Fire TBL RST Fire-Unbypass Fire unbypass FKP-Tamper-Rst FKP:Tamper RST FKP-Tamper FKP:Tamper Guard-Tour-Fail Guard Tour Fail Guard-Tour-Pass Guard tour pass Guard-Tour-Start Guard Tour Start Guard-Tour-Station Guard tour station HA-Burg-Bell-Sil HA Burg Bell Silenced HA-Fire-Bell-Sil HA Fire Bell Silenced HA-Pls-Burg-Bll-Sil HA Pulsed Burg Bell Silenced Hstory-Log-Auto-Dmp History Log Auto dump Hst-Lg-Aut-Dmp-Fail History Log Auto dump fail Home-Auto-Close Home Automation Close Home-Auto-Open Home Automation Open Keyfob-Lb KeyFob LB Keyfob-Lb-Rst KeyFob LB RST Keypad-Ambush Keypad Ambush Keypad-Bus-Fail Keypad bus fail Keypad-Bus-Rst Keypad bus RST Keypad-Fire Keypad Fire Keypad-Medical Keypad Medical Keypad-Panic Keypad Panic Keypad-Tamper Keypad Tamper Keypad-Tamper-Rst Keypad Tamper RST KP-Fail KP Fail KP-Restore KP Restore Low-Bat Low Bat Low-Bat-Rst Low Bat RST Low-RF-Sgn-Level Low RF Sig Level Nt-Log-Cleared NT:Log cleared One-Man-Test-Alarm One Man test Alarm One-Man-Test-Rst One Man test RST Open OPEN Panel-Gnd-Flt Panel Ground fault Panel-Gnd-Flt-Rst Panel Ground fault RST Panel-Reset-Normal Panel Reset Normal Panel-Reset-Watch Panel Reset Watchdog Panel-Sgn-Ckt-Flt Panel Signal ckt fault Panel-Sgn-Ckt-Rst Panel Signal ckt RST PC-Pres-Log-Up-Load PCPreset Log up load Pcd-Callback-Fail PCD Callback failure Pcd-Forced-Watchdog PCD forced WatchDog Pgm-Change Program change Pls-Burg-Bell-Sil Pulsed burg bell silenced Printer-Fail Printer Fail Printer-Restore Printer Restore Q-Loader-Ver-Fail Quickloader Verify fail Ql-Bypass QL Bypass Ql-Conn-Dealer QL Connection dealer Ql-Conn-Technical QL Connection technical Ql-Conn-Terminated QL Connection terminated Ql-Device-Ctl QL Device control Ql-Dnload QL Dnload Ql-Hst-Log-Act QL Histroy log activity Ql-Keypad-Reset QL Keypad reset Ql-Srv-Code QL Service Code Ql-System-Shut-Down QL System shut-down Ql-Tbl-Bypass QL TBL bypass Ql-Upload QL Upload Ql-Verify QL Verify Ql-Log-Cleared QL:Log cleared Ql-Remote-Relay-Ctl QL:Remote relay control RBM-Fail RBM Fail RBM-Rst RBM RST RBM-Sgn-Crc-Flt RBM Sig Circuit fault RBM-Sgn-Crc-Flt-Rst RBM Sig Circuit Fault RST Relay-Off Relay Off (#1?) Relay-Offx Relay Off (#2?) Relay-On Relay On (#1?) Relay-Onx Relay On (#2?) Reset-Sensor-Watch Reset sensor watch Restore Restore RF-Tx-Low-Bat RF Tx Low Bat RF-Tx-Low-Bat-Rst RF Tx Low Bat RST RF-Tx-Sup-Fail RF Tx Supv Fail RF-Tx-Sup-Rst RF Tx Supv RST RF-Tx-Tamper RF Tx Tamper RF-Tx-Tamper-Rst RF Tx Tamper RST RFEZM-Fail RFEZM Fail RFEZM-Rcv-Jam RFEZM receiver Jam RFEZM-Rcv-Jam-Rst RFEZM receiver jam RST RFEZM-Rst RFEZM RST RFEZM-Tamper RFEZM Tamper RFEZM-Tamper-Rst RFEZM Tamper RST Security-Bypass Security Bypass Self-Test-Failure Self Test Failure Sensor-Fail Sensor Fail Srv-Msg-Activated Service message activated Sil-Pls-Burg Silence Pulse Burg t/o Tbl-Rst TBL RST Telco-1-Fail Telco 1 fail Telco-1-Rst Telco 1 RST Telco-2-Fail Telco 2 fail Telco-2-Rst Telco 2 RST Telem-Failure Telemetry Failure Telem-Failure-Rest Telemetry Failure Restore Telem-Restore Telemetry Restore Telem-Trouble Telemetry Trouble Test-Timer Test timer Time Time Trouble Trouble Unbypass Unbypass User-Mem-Fail User mem fail User-Pgm-Mode-Act User program mode activity V61-FEZM-GndFlt V61:FEZM Ground fault V61-FEZM-GndFlt-Rst V61:FEZM Ground fault RST Water-Alarm Water alarm Water-Rst Water RST Water-Tbl Water TBL Water-Tbl-Rst Water TBL RST Zone-Normal Zone NORMAL Zone-Open Zone OPEN Zone-Short Zone SHORT -- Mark Gilmore Omnipotence (ECS home automation software) http://www.usit.com/omnip 423-745-0026 Bill Walters wrote: > > Mark, > > Not sure what I said that created such an outburst from you on the NAPCO > stuff..... but it seems as I certainly got your tail feathers ruffled... > > If I offended you with my comments, then I apologize, although I fail to see > how you could have been offended....??? > > My comments were that NAPCO expects software that is integrated with their > panel to be "turnkey" and do everything for the user. Perhaps integrated by > the user's dealer..... My specific comment was "Not so for us ECS users"; > due to the power/flexibility of ECS, we can do just about anything we want, > once we bust into the device we're integrating..... > > Frustrating? Yes... Particularly when you know there is all this power, > just waiting to be harnessed....... but you need a map to find the treasure. > I was hoping for a peek at the map, Mark. > > Again, if I offended, you have my apologies, for I am one of your, and ECS's > supporters... > > Bill Walters