Re: [ECS] Access Control Using ECS
Graeme Kelly
Tue, 25 Jul 2000 14:33:53 +1200

Kevin

I use the X10 security alarm console. I  soldered a socket in series with the
"armed" LED in the console and plugged the low voltage detecting circuit of
an X10 Powerflash unit in to it, and plugged the Powerflash into the mains.
The Powerflash transmitted a X10 on or off code to ECS so it knew when the
house was disarmed or armed. Upon disarming from outside with X10 keyring
remote and receiving the Powerflash signal, ECS events sent another X10 code
to switch on a 12V plug pack connected to the electric door lock (see
Smarthome catalogue) for two seconds. The solenoid receiving 12V ac buzzes
revolving the door frame socket and then you can push the door open (even
after 2 seconds) without using the key. Great when you have an armful of gear!
ECS also switches off Rex10 barking dog alarm and switches on hall lights (if
dark) for 2 minutes, raises heating output to "in residence" level if needed,
and then says "Good evening (morming/afternoon) Kevin". When you leave and set
the alarm, ECS does the reverse with a couple of minutes delay.

If you're worried about someone activating the Powerflash unit by transmitting
the 256 codes until they hit the right one, you can put two of them with low
voltage inputs in series. Unfortunately, if you want a deadlock as well,
you'll have to unlock this first with a key. Other better alarm systems are
even easier to interface with ECS.

Cheers!

Kevin Trainor wrote:

> ----- Original Message -----
> From: Mark Gilmore <omnip@usit.net>
> To: <ecs-list@netbloc.com>
> Sent: Sunday, July 23, 2000 6:24 AM
> Subject: Re: [ECS] Access Control Using ECS
>
> > Kevin,
> > When researching for a hotel spec a while back,
> > I ran across a lock at http://www.smarthome.com/5190S.html ($40).
> > I think this device locks the door when low-voltage is removed,
> > and unlocks when it is applied. ECS could control this line via
> > the SECU-16 (above).
> > --
> > Mark Gilmore
> > Omnipotence (ECS home automation software)
> > http://www.usit.com/omnip
> > 423-745-0026
> > Hours: Mon-Sat, 9AM-8PM/EST
> >
> >
> > > Kevin Trainor wrote:
> > >
> > > I am not yet an ECS user.  I am considering using ECS for an access
> > > control application at my home.  What I would like to do is to control
> > > access to entry doors using a strike plate with access control based
> > > upon a proximity reader.  I have found a number of dedicated systems
> > > to do this.  But, it seems to me that I ought to be able to do pretty
> > > much the same thing using ECS and some standard parts.
> > >
> > > My question:  has anyone else implemented home access control using
> > > ECS.  I am interested in applications that use either a keypad or
> > > proximity reader.  If you have success in this area, I would be
> > > interested in what parts you used and where you acquired them.  Also,
> > > which ECS interface did you choose to implement this with?
> > >
> > > I am also interested in hearing about anyone's experience in
> > > interfacing ECS to a dedicated access control system in order to keep
> > > ECS informed about access events without having ECS actually control
> > > door access itself.
> > >
> > > Please post reply or email me directly:  kevin@thetrainors.com
> > >
> > > Thanks.
> > >
> > > Kevin
> >