| ECS-L Home Automation and Security Archives |
| Subject: From: Date: | RE: [ECS] X-10 communication help... Stephen Weiss Mon, 2 Oct 2000 09:25:25 -0400 |
All, After a (what started out wanting to be a brief, but turned out to be a long) di » -----Original Message----- » From: A.J. Griglak [mailto:aj@griglak.com] » Sent: Saturday, September 30, 2000 1:25 PM » To: ecs-list@netbloc.com » Subject: RE: [ECS] X-10 communication help... » » » I'm not sure if this will help your situation, but I would » recommend the » following modification to anyone who has the TW523. I did it » to my TW523, » and it makes a big difference. Before the hack, there was a » very noticible » 3-5 second delay between commands. Now the delay is no more » than a second. » » Disregard the 110v to 220v at the top of the page. Start at » "Modification » to improve reliability" » http://www.geocities.com/ido_bartana/modifying_power_line_inte » rface.htm » » You can also read more about it on this thread: » » http://x71.deja.com/=km/viewthread.xp?mhitnum=15&AN=584620831. » 1&frpage=threa » dmsg_ct.xp&recnum=%3c881gi2$rh@news.or.intel.com%3e%231/1&back » =comp.home.aut » omation » » (It's a long one, so you might need to manually cut and paste » it into your » browser as opposed to clicking on it... » » Good luck! » » -=A.J. » » -----Original Message----- » From: Stephen Weiss [mailto:seweiss@fast.net] » Sent: Friday, September 29, 2000 3:09 PM » To: ecs-list@netbloc.com » Subject: RE: [ECS] X-10 communication help... » » » A.J. » » I actually did e-mail ADI, and they told me that the in-wall » transmitters transmit the extended X-10 signals that the » TW523 won't forward onto the Ocelot or any other controller. » » What confuses me about this is that the in-line modules that » I have work fine, so I don't see what the extended X-10 has » to do with anything, and to me the TW523 should pick these » up. The TW523 is supposed to be two-way, is it not? » » Also, I did joing the mailing list prior to receiving your » e-mail. Thanks for the suggestion. » » I wanted to try out the C-Max software just to make sure » things were working, but I ran across this issue. I plan » to move onto ECS, if I can (or even can't) get a worthwhile » answer to this. » » Regards, » Stephen Weiss » » » » -----Original Message----- » » From: A.J. Griglak [mailto:aj@griglak.com] » » Sent: Friday, September 29, 2000 3:03 PM » » To: ecs-list@netbloc.com » » Subject: RE: [ECS] X-10 communication help... » » » » » » Hmmm... Sounds like a ADI question really. Go to » » http://www.futurestandard.com/mailinglists.htm and join the » » CPU-XA mailing » » list. CPU-XA is what they used to call the Ocelot. I have » » an Ocelot since » » December, but only used the C-MAX software for about 3 » » minutes. Since then, » » I've used ECS exclusively. I'm sure if you try both, you'll » » come to the » » same conclusion. » » » » Good Luck » » » » -=A.J. » » » » -----Original Message----- » » From: Stephen Weiss [mailto:seweiss@fast.net] » » Sent: Friday, September 29, 2000 9:52 AM » » To: ecs-list@netbloc.com » » Subject: [ECS] X-10 communication help... » » » » » » All, » » » » I just received an Ocelot with a TW523 X-10 communication unit. » » » » I have a number of in-wall controllers which I use to control X-10 » » in-line modules and outlets. When I use the supplied Ocelot » » software to monitor the X-10 commands and I use the in-wall » » controllers to transmit a message, I don't see it in the X-10 log. » » Is this typical operation? Shouldn't I see the X-10 messages » » from an in-wall controller? I know the messages are going out » » because the in-line units work fine. » » » » Any/All help is greatly appreciated, » » Stephen Weiss » » seweiss@fast.net » » »