Re: [ECS] Item Changes in last two betas
Mark Gilmore
Wed, 11 Oct 2000 21:06:51 -0400

Hi Brian,
I noted this changes in a prev email (see below).

I know of no changes effecting "performance".
But if I am to address it, I need a very specific
description of the problem.

	4.4.010 (10/09/00)

*   88)	The "CPU-XA" "module" designation for various OCELOT-related
Types
	has been changed to "Main".
	To make the required changes, please enter the following:
		EDM ECS.CFG
		C/ :CPU-XA :Main
		W
		Q

    89)	As the LEOPARD IS an OCELOT with additional touch-screen
features,
	ECS can now support the LEOPARD as both (i.e. no OCELOT is needed).
	To do this, define a PLC-INTERFACE-K Item and a TOUCH-SCREEN-K
	Item whose module ID is "Main".

    90)	We have dropped support for the CP290 (old 1-way X10
transmitter).

*   91)	The following Types have been renamed
	(please change as required in ECS.CFG):

	Old			New
	----------------	---------------
	IR-Interface-1D		IR-Interface-D
	IR-Interface-2B		IR-Interface-B
	IR-Interface-2C		IR-Interface-C
	PLC-Interface-2A	PLC-Interface-A
	PLC-Interface-2B	PLC-Interface-B
	PLC-Interface-2C	PLC-Interface-C
	PLC-Interface-2D	PLC-Interface-D
	PLC-Interface-2G	PLC-Interface-G
	PLC-Interface-2H	PLC-Interface-H
	PLC-Interface-2I	PLC-Interface-I
	PLC-Interface-2J	PLC-Interface-J
	PLC-Interface-2K	PLC-Interface-K

*   92)	The DISPLAY State of the TOUCHSCREEN-K Item has been removed,
	as it did not work as intended. To display a specific screen,
	just set the Item to that screen's # (0-25).

    93)	For ECS/WWW users who wish to use a CUSTOMIZED version of
MAIN.HTM
	(and PREVENT ECS from re-generating it when requested), create a TEXT
	Item named "ECS_MAIN_HTM_GEN" whose Text-Line is "1".

    94)	For ECS/WML users who wish to use a CUSTOMIZED version of
MAIN.WML
	(and PREVENT ECS from re-generating it when requested), create a TEXT
	Item named "ECS_MAIN_WML_GEN" whose Text-Line is "1".
-- 
Mark Gilmore
Omnipotence (ECS home automation software)
http://omnipotencesoftware.com
423-745-0026
Hours: Mon-Sat, 9AM-8PM/EST


> Brian McGinnis wrote:
> 
> Have there been some changes to interface naming?
> I recently download beta 9 and 10 and both seem to do the same thing.
> The version I'm currently using is 4.4.006.
> 
> to be specific:
> 
> 1. It seems that PLC-Interface-2C and PLC-Interface-2K types have been
> changed to PLC-Interface-C and PLC-Interface-K?  When I loaded the
> betas it complained about these and I had to drop the "2" from them to
> get them to work.
> 
> 2.  Performance seems to have dropped off.  It used to be when ECS
> loaded, I could login while it was sending X10 commands out the
> interface.  Now it practically stalls for the 30 seconds or so and it
> seems to take longer to send X10 commands.
> 
>

  subject (prev) or (next) | time (prev) or (next) | author (prev) or (next) | view more subjects




Services provided by [NetBloc]®! NetBloc Solutions Inc.
Terms of use. Indexing software (c) 1999 Lin-De, Inc
.