| Subject: From: Date: | Re: [ECS] Item Changes in last two betas Mark Gilmore Wed, 11 Oct 2000 21:06:51 -0400 |
Hi Brian,
I noted this changes in a prev email (see below).
I know of no changes effecting "performance".
But if I am to address it, I need a very specific
description of the problem.
4.4.010 (10/09/00)
* 88) The "CPU-XA" "module" designation for various OCELOT-related
Types
has been changed to "Main".
To make the required changes, please enter the following:
EDM ECS.CFG
C/ :CPU-XA :Main
W
Q
89) As the LEOPARD IS an OCELOT with additional touch-screen
features,
ECS can now support the LEOPARD as both (i.e. no OCELOT is needed).
To do this, define a PLC-INTERFACE-K Item and a TOUCH-SCREEN-K
Item whose module ID is "Main".
90) We have dropped support for the CP290 (old 1-way X10
transmitter).
* 91) The following Types have been renamed
(please change as required in ECS.CFG):
Old New
---------------- ---------------
IR-Interface-1D IR-Interface-D
IR-Interface-2B IR-Interface-B
IR-Interface-2C IR-Interface-C
PLC-Interface-2A PLC-Interface-A
PLC-Interface-2B PLC-Interface-B
PLC-Interface-2C PLC-Interface-C
PLC-Interface-2D PLC-Interface-D
PLC-Interface-2G PLC-Interface-G
PLC-Interface-2H PLC-Interface-H
PLC-Interface-2I PLC-Interface-I
PLC-Interface-2J PLC-Interface-J
PLC-Interface-2K PLC-Interface-K
* 92) The DISPLAY State of the TOUCHSCREEN-K Item has been removed,
as it did not work as intended. To display a specific screen,
just set the Item to that screen's # (0-25).
93) For ECS/WWW users who wish to use a CUSTOMIZED version of
MAIN.HTM
(and PREVENT ECS from re-generating it when requested), create a TEXT
Item named "ECS_MAIN_HTM_GEN" whose Text-Line is "1".
94) For ECS/WML users who wish to use a CUSTOMIZED version of
MAIN.WML
(and PREVENT ECS from re-generating it when requested), create a TEXT
Item named "ECS_MAIN_WML_GEN" whose Text-Line is "1".
--
Mark Gilmore
Omnipotence (ECS home automation software)
http://omnipotencesoftware.com
423-745-0026
Hours: Mon-Sat, 9AM-8PM/EST
> Brian McGinnis wrote:
>
> Have there been some changes to interface naming?
> I recently download beta 9 and 10 and both seem to do the same thing.
> The version I'm currently using is 4.4.006.
>
> to be specific:
>
> 1. It seems that PLC-Interface-2C and PLC-Interface-2K types have been
> changed to PLC-Interface-C and PLC-Interface-K? When I loaded the
> betas it complained about these and I had to drop the "2" from them to
> get them to work.
>
> 2. Performance seems to have dropped off. It used to be when ECS
> loaded, I could login while it was sending X10 commands out the
> interface. Now it practically stalls for the 30 seconds or so and it
> seems to take longer to send X10 commands.
>
>